Features
The Nanolevel submersible level transmitter utilizes a ceramic measuring cell for high resolution and excellent stability in applications with very low pressure ranges. The dual output feature ensures compatibility with most pump controllers and SCADA systems.
· Gold-plated ceramic sensing diaphragm
· Excellent 0.1% FS static accuracy, 0.25% Total Error Band (TEB)
· 316L stainless construction
· 2-year warranty covers defects in materials and workmanship
· User-rangeable analog output ensures compatibility as requirements change
· RS485 modified-MODBUS compatible interface allows up to 128 transmitters
on a single bus
· Standard dual (analog & RS485) outputs simplify interface to controls, data
collection, and telemetry systems
· Standard 3-day lead time
Specifications
Relative Pressure Ranges | 0 to 4 in WC and 0 to 120 in WC |
---|---|
Output | 4 to 20 mA + RS485 |
Accuracy, Static at 25° C | 0.1% FS |
Accuracy, Total Error Band | Standard: 0.25% BR TEB |
Compensated Temp. Range | 10 to 50° C |